Managing heating with electrical-load data

8allocate built an energy-management controller that integrated with heating equipment and supported remote, automatic and manual operation.

Business case

Heating equipment needed to be controllable remotely while retaining automatic and manual operating modes.

The system also needed to use electrical-load information to manage power consumption and account for electricity tariffs when operating the heating equipment.

What we delivered

The team integrated an embedded controller with the heating equipment and built the electrical-load analysis and power-consumption control.

Users could change operating modes remotely. The same system supported automatic and manual operation, with the ability to account for tariffs in heating operation.

How it worked

Electrical-load analysis and heating control

Equipment signal and control path

  1. Heating equipmentProvides electrical-load signals.
  2. Signal acquisition and analysisElectronics capture the signal. The controller analyses the load using FFT.
  3. Embedded controllerUses load information, tariff inputs and the selected operating mode.
  4. Heating controlAdjusts how the equipment operates and manages power consumption.

Operating inputs to the controller

  1. Operating mode and tariff informationThe selected remote, automatic or manual mode and the applicable tariff.
  2. Embedded controllerApplies the selected operating mode.

Functional view of the delivered controller. The diagram shows how equipment signals and operating inputs inform heating control.

Technical notes

  • The solution used STM32 and embedded Linux, with PCB integration, analogue-to-digital and digital-to-analogue conversion, and galvanic isolation.
  • The implementation used fast Fourier transform (FFT) for electrical-load analysis. The project included hardware integration and testing.

Business outcomes

The delivered controller used equipment data to manage power consumption and let users change heating modes remotely. Automatic and manual operation were available through the same system.

Remote control

Users could adjust heating modes remotely.

Tariff-aware operation

Heating operation could account for electricity tariffs.

Multiple operating modes

Automatic and manual control were supported in one system.

The case documents delivered capabilities and hardware testing. It does not report measured reductions in energy consumption or cost.